Use zone type 08 for hardwired smoke detectors and 88 for wireless smoke detectors. Regardless of how location 013 is programmed, a fire zone should have a 5.6K Ohm resistor wired across the normally open terminals so the fire alarm will short the resistor out when it is activated.

  • 2 - OFF = Single end of line (use 2x 5.6k Ohm Resistors)įire zones must be wired differently.
  • 2 - ON = Double end of line (use one 5.6k Ohm Resistor).
  • 1 - OFF = Use resistor value set in option 2 below.
  • 1 - ON = Normally closed zones (use no resistor, just closed loops).
  • To set the zone EOL resistor value, go to location 013: + Zone wiring detailsĪll hardwired zones can be either normally closed (no resistors), single EOL (with a 5.6K Ohm resistor), or double end of line (where you have two 5.6K Ohm resistors, one across the alarm contact and one in series with the tamper). Power the panel up and after 10 seconds everything should be defaulted and you can remove the wire loop. Get a short loop of wire and link zone 1 and PGM 1. Next, remove any wiring from the zone 1 terminal and the PGM 1 terminal. This will revert all programming back to factory defaults. If you are in a location, just push # a couple times and you will get out. To exit programming mode completely, you need to press # from 'programming limbo'. Pressing * when programming data will change to Hexicidecimal input, this can be utilized when programming account numbers. Pressing # will take you back out of the location and into 'programming limbo', where you can enter another location. Once in a location, you can either enter data or toggle the 8 options on/off. When programming a DSC you need to enter a 3-digit location number. You should hear 3 beeps, one long beep means incorrect code.

    #Dsc alarm panel program time code

    To enter programming mode, press * 8 then enter the installer code (default 5555).

    #Dsc alarm panel program time install

    + Quick install cheat sheet + Entering programming mode The DSC 1832 shares the same programming as the 1616, and the 1864 as they are basically the same panel, with a different number of zones, etc.

    #Dsc alarm panel program time manual

    This works 100% just like the manual describes. Thus, you have to ground Z1 to PGM and power the system up for 10 seconds and then power it off, remove the jumper and then power it back on. To do this you have to short the zone 1 pin (not the z1 common pin) with the PGM1 pin. The following applies to all PowerSeries panels, which include PC1616, PC1832, PC5010, PC5015 and others. Is the yellow ‘trouble’ LED lit on your alarm keypad? DSC uses LED codes to indicate trouble details for all keypads that don’t have an LCD readout display. Panel waiting for 3 digit section number. Quick Guide For Programming DSC Powerseries Alarms. How to Reset an Ademco Alarm After Replacing the Battery 4. If 2 is illuminated or appears on the display, the system does not have electrical power. Change the battery per the panel's instruction manual if a number 1 appears on the display or the 1 zone is illuminated. Troubleshoot Problems on the DSC Home Security System. button followed by 6 Enter your system’s master code (If you are an FMC customer and do not know your system’s master code, call FMC’s Service Department.

    #Dsc alarm panel program time how to

    Here are step-by-step instructions on how to change the date and time on the keypad on your DSC Power Series security alarm panel: Press the.